- 15 -
Actual Sample Size vs. Sample Size Control for Various Head Heights
0
200
400
600
800
1000
1200
1400
1600
1800
2000
0 250 500 750 1000 1250 1500 1750 2000 2250
Actual Sample Size (ml)
Appendix A: Sample Size Calibration
Use the following graph to see how sample size changes with head height. The Sample
Size controls on the control panel are calibrated at a height of 4 feet. Increasing the head
height decreases the sample size by a predictable amount. To determine the appropriate
Sample Size setting for a desired volume; find the sample size on the horizontal axis, follow
straight up to the line corresponding to your head height, then look across to the vertical
axis and read the setting for the Size control on the control panel.