Xylem H-424MS V1.0 User Manual

Browse online or download User Manual for Equipment Xylem H-424MS V1.0. Xylem H-424MS V1.0 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 25
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Spread Spectrum
SDI-12 Radio Bridge
Owner’s Manual
Model
H-424MS
Version 1.0
(for system revision “C” or higher)
NOTICE
This product embodies technology that is confidential and proprietary technology of DESIGN
ANALYSIS ASSOCIATES, INC., and which is protected by United States copyright laws and
international copyright treaty provisions, and/or by contract and applicable laws of trade secrecy.
These include all Software, Printed Circuit Board Artwork, Schematic Diagrams, and
Technologies applied therein. The enclosure encasing the electronics of this instrument may not
be opened without written consent of DESIGN ANALYSIS ASSOCIATES, INC., and any
attempt to do so without such written authorization constitutes a breach of contract and will also
void any applicable warranty for the product.
Design Analysis Associates, Inc.
75 West 100 South
Logan, UT 84321 USA
Phone: (435) 753-2212
Fax: (435) 753-7669
Internet: www.waterlog.com
Page view 0
1 2 ... 25

Summary of Contents

Page 1 - Owner’s Manual

Spread SpectrumSDI-12 Radio BridgeOwner’s ManualModelH-424MSVersion 1.0 (for system revision “C” or higher)NOTICEThis product embodies technology that

Page 2

1-2 Operation H-424MSNormally the H-424MS operates as a transparent SDI-12 to SDI-12 bridge. However, in order towake the remote end of the li

Page 3 - Table of Contents

H-424MSOperation 1-31.4 Programming Your Data RecorderYou must prepare your data recorder to receive and record SDI-12 data from the sensorsattache

Page 4

1-4 Operation H-424MSThe H-424MS modules comes from the factory with the following settings:SDI Address: 0Wakeup Interval: 15 SecondsInactivity

Page 5 - Warranty

H-424MSOperation 1-51.7 Making SDI-12 ConnectionsThe H-424MS enclosure has a 4-pin SDI-12 connector. The power for the H-424MS and theradio is suppl

Page 6

1-6 Operation H-424MSremain on for 30 seconds. Before the 30 second inactivity time elapses, issue a “aM!” or othercommand to your sensor and

Page 7

H-424MSOperation 1-71.9 FCC RestrictionsThis equipment has been tested and found to comply with the limits for a Class B digital device,pursuant to P

Page 9 - Operation

Chapter 2SDI-12 Command and Response ProtocolH-424MS SDI-12 Command and Response Protocol 2-12.1 SDI-12 Command and Response ProtocolNormally the H-

Page 10 - H-424MS

2-2 SDI-12 Command and Response Protocol H-424MSExample of a H-424MS "aM!" command: Command Response Time Values Description------------- --

Page 11 - H-424MS

H-424MS SDI-12 Command and Response Protocol 2-32.3 Send Data CommandThe Send Data command returns sensor data generated as the result of previous &

Page 13

2-4 SDI-12 Command and Response Protocol H-424MSExample of a H-424MS "aV!" command: Command Response Time Values Description------------- --

Page 14

H-424MS SDI-12 Command and Response Protocol 2-52.5 Send Acknowledge CommandThe Send Acknowledge Command returns a simple status response which incl

Page 15

2-6 SDI-12 Command and Response Protocol H-424MSExample of a H-424MS "aI!" command:

Page 16

H-424MS SDI-12 Command and Response Protocol 2-7Example of a H-424MS Extended "Read Wake Interval" command:Command Response Time Values Des

Page 17 - Chapter 2

2-8 SDI-12 Command and Response Protocol H-424MSExample of a H-424MS Extended "Write Wakeup Interval" command:Command Response Time Values D

Page 18

Appendix ASpecificationsH-424MSSpecifications A-1ProtocolLocal: SDI-12Remote: SDI-12Type: Transparent SDI-12.Works with all SDI-12commands includingex

Page 19

Table of ContentsUser Agreement/WATERLOG® Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . W-1Chapter 1 Operat

Page 21

User Agreement/WATERLOG® WarrantyH-424MS User Agreement/WATERLOG® Warranty W-11. NATURE OF THE PRODUCTThis agreement accompanies a pressure measuri

Page 22 - S#nnnnnnVkkk

W-2 User Agreement/WATERLOG® Warranty H-424MS4. TERMUSER may enjoy these rights only as long as their possession of the PRODUCT shall continue tob

Page 23

H-424MS User Agreement/WATERLOG® Warranty W-3(iii) EXCEPT FOR THE EXPRESS WARRANTIES ABOVE, DESIGNANALYSIS SPECIFICALLY DISCLAIMS ALL OTHER WARRANTI

Page 25 - Specifications

Chapter 1Operation H-424MSOperation 1-11.1 IntroductionThe WATERLOG® H-424MS is a spread spectrum SDI-12 radio bridge. The radio link is easy touse a

Comments to this Manuals