Xylem FP111, FP211, & FP311 GLOBAL WATER FLOW PROBE User Manual

Browse online or download User Manual for Tools Xylem FP111, FP211, & FP311 GLOBAL WATER FLOW PROBE . Xylem FP111, FP211, & FP311 GLOBAL WATER FLOW PROBE Users Manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 19
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Global
Water
800-876-1172
globalw.com
1
FP111-FP211-FP311 Global Water Flow Probe
User’s Manual
151 Graham Road
P.O. Box 9010
College Station, TX 77842-9010
T: (800) 876-1172
Int’l: (979) 690-5560, F: (979) 690-0440
01-994
Publication Number 38330112
Page view 0
1 2 ... 19

Summary of Contents

Page 1 - User’s Manual

Global Water 800-876-1172 • globalw.com 1 FP111-FP211-FP311 Global Water Flow Probe User’s Manual 151 Graham Road P.O. Box 9010 College St

Page 2

Global Water 800-876-1172 • globalw.com 10 last reset. Press the RESET button when beginning to take any new measurement. Save to Memory Whe

Page 3 - III. Description

Global Water 800-876-1172 • globalw.com 11 Setup Menu To enter the setup menu, press and hold the MENU button for 2 seconds. Each press of the M

Page 4 - IV. General Instructions

Global Water 800-876-1172 • globalw.com 12 Delete All From the Delete All menu screen, press SET to delete all stored data. The upper displ

Page 5

Global Water 800-876-1172 • globalw.com 13 Set Calibration Factor From the Set Calibration menu screen, press Set to change the calibration facto

Page 6 - V. Average Velocity

Global Water 800-876-1172 • globalw.com 14 VII. Specifications Range: 0.3-19.9 FT/S (0.1-6.1 M/S) Accuracy: 0.1 FT/S (0.1 M/S) Averaging: True

Page 7

Global Water 800-876-1172 • globalw.com 15 b. Battery: The flow probe computer’s battery is not replaceable. It should last approximately 5 year

Page 8

Global Water 800-876-1172 • globalw.com 16 magnet is necessary to generate the signal for the computer. c. Remove the computer holder from the pol

Page 9 - Main Display

Global Water 800-876-1172 • globalw.com 17 Be prepared to describe the problem you are experiencing including specific details of the application,

Page 10 - Save to Memory

Global Water 800-876-1172 • globalw.com 18 Appendix A: Calculations for Partially Filled Round Pipes B C B C 0.01 0.0013 0.51 0.4027 0.02

Page 11 - View Data

Global Water 800-876-1172 • globalw.com 19

Page 12 - Set Flow Units

Global Water 800-876-1172 • globalw.com 2 Congratulations on your purchase of the Global Water Flow Probe. This instrument has been quality tested

Page 13 - Set Calibration Factor

Global Water 800-876-1172 • globalw.com 3 I. Flow Probe Checklist a. Flow Probe: FP111, FP211 or FP311 b. Flow Probe Computer c. Manual d.

Page 14 - VIII. Maintenance

Global Water 800-876-1172 • globalw.com 4 The flow computer incorporates true velocity averaging for the most accurate flow measurements. The compu

Page 15 - IX. Trouble Shooting

Global Water 800-876-1172 • globalw.com 5 c. To extend battery life, a low power mode is incorporated that will take effect after 5 minutes of ina

Page 16

Global Water 800-876-1172 • globalw.com 6 V. Average Velocity The Flow Probe is used to measure the average water velocity. Stream flow velocity

Page 17 - X. Warranty

Global Water 800-876-1172 • globalw.com 7 The Flow Probe can be used in three ways to determine average velocity in a stream. a. For small stream

Page 18

Global Water 800-876-1172 • globalw.com 8 flow profile at the center of each subsection: zero the averaging function and move the Flow Probe vertic

Page 19 - 800-876-1172

Global Water 800-876-1172 • globalw.com 9 VI. Computer Operation Main Display In the main display, the 4 buttons are labeled as shown. The M

Comments to this Manuals

No comments