H-3301/3311
OWNERS MANUAL
V2.1
D34 0514
INCREMENTAL SHAFT ENCODER WITH SDI-12 AND QUADRATURE OUTPUTS
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1 - H-3301/3311

H-3301/3311 OWNERS MANUALV2.1D34 0514INCREMENTAL SHAFT ENCODER WITH SDI-12 AND QUADRATURE OUTPUTS

Page 2 - CONTENTS & WARRANTY

8H-3311 LCD DISPLAYThe H-3311 has the same functionality as the H-3301 with the addition of a built in display and manual offset adjustment. The LCD d

Page 3

9SDI-12 COMMAND & RESPONSE PROTOCOL03 /

Page 4 - INTRODUCTION

10SDI-12 COMMAND & RESPONSE PROTOCOLThis is a brief description of the Serial Digital Interface (SDI-12) Command and Responseprotocol used by the

Page 5 - Operation

11SDI-12 Command & Response ProtocolCommand DescriptionaM! Make MeasurementaMC! Make Measurement with CRCaC! Make Concurrent MeasurementaCC! Make

Page 6

12SDI-12 COMMAND & RESPONSE PROTOCOL ttt is a three digit integer (000-999) specifying the maximum time, in seconds, the sensor will take t

Page 7 - Making Output Connections

The “Concurrent Measure with CRC” command causes a measurement sequence to be performedwith a CRC appended to the data. Data values generated in respo

Page 8

14SDI-12 COMMAND & RESPONSE PROTOCOLThe “Send Data” command returns sensor data generated as the result of previous “aM!”, “aC!” or“aV!” commands.

Page 9

The “Send Acknowledge” command returns a simple status response which includes the address ofthe sensor. Any measurement data in the sensor’s buffer i

Page 10 - H-3311 LCD DISPLAY

16SDI-12 COMMAND & RESPONSE PROTOCOLThe “Verify” command causes a verify sequence to be performed. The result of this command issimilar to the “aM

Page 11 - RESPONSE PROTOCOL

The “Change Sensor Address” command allows the sensor address to be changed. The address isstored in non-volatile EEPROM within the sensor. The H-3301

Page 12

This user manual is a guide for the H-3301/3311 shaft encoder. For more information, updated manuals, brochures, technical notes, and supporting soft

Page 13 - Measure Command

A is an upper-case ASCII character. n is the new sensor address to be programmed (“0-9”, “A-Z”, “a-z”, “*”, “?”).NOTE: To verify the new addres

Page 14

19SDI-12 Command & Response ProtocolThe H-3301/3311 processes the raw shaft encoder position with a mX+b equation. The slope (m)and offset (b) ter

Page 15

20SDI-12 COMMAND & RESPONSE PROTOCOLThe H-3301/3311 processes the raw shaft encoder position with a mX+b equation. The slope (m)and offset (b) ter

Page 16

21SDI-12 Command & Response ProtocolGeneralInput: Shaft PositionOutputs: SDI-12 & 2-Wire QuadratureResolution (SDI): 200 counts/rev

Page 17 - Send Acknowledge Command

1) The tissue in plants that brings water upward from the roots;2) a leading global water technology company.We’re 12,000 people unified in a common pu

Page 18

1Contents & Warranty“WATERLOG™ PRODUCTS MANUFACTURED BY YELLOW SPRINGS INSTRUMENTS CO., INC. are warranted by Yellow Springs Instruments Co., Inc.

Page 20

The H-3301/3311 is a precision shaft encoder with a resolution of two hundred counts per revolution (0.005 ft with a 1 ft circumference pulley). The H

Page 21

The H-3301/3311 comes from the factory with the following settings: SDI Address: 0 Slope: 0.0050 Offset: 0.000With these values Stage will be in un

Page 22

5Introductionposition count with a software flag or “signature”. If the power is removed momentarily the H-3301/3311 will resume operation using the c

Page 23 - Specifications

6INTRODUCTION• Make certain the encoder’s output does not go negative or more than +5.0 Volts• Make certain the ground and power pins are connected to

Page 24

7H-3311 LCD DISPLAY02 /