4.) Installation
The preferred installation position is vertical with the pump
facing down. When horizontal installation is unavoidable, take
care to purge the remaining air since this is more difficult in the
horizontal position. Please make sure that beneath the unit (or
on the pump side when installing horizontal) a free space of
approx. 1.2 inch remains which is necessary to service the
pump in case of trouble.
The unit must be installed on a non-flammable surface and
must be installed indoors. Avoid any flammable materials in the
immediate vicinity of the unit.
The unit is mounted using the mounting grooves at the bottom
rear of the junction box.
5.) Electrical connection
Important advice: Electrical work may only be performed by a
properly licensed Electrician and has to conform to all relevant
codes and requirements.
All internal connections of the EHR are pre-wired so that only
the mains connection and, if applicable, the connection of an
external room thermostat (Model Laing RTS) or room
thermostat with timer (Model Laing RTU) need to be done.