Xylem EHR IM Electrical heater series EHR (obsolete) User Manual Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
Adding room thermostat
RTS;
Mains connection on
terminals L and N. Ground
connection on the ground
terminal on the brass
body.Remove jumper wire
between terminals 5 and 6
of the EHR terminals and
connect those to room
thermostat connections 1
and 3.
Adding timer thermostat
RTU;
Mains connection on
terminals L and N. Ground
connection on the ground
terminal on the brass
body.Remove jumper wire
between terminals 5 and 6
of the EHR terminals and
connect those to timer
thermostat connections.
Standard:
Mains connection on
terminals L and N. Ground
connection on the ground
terminal on the brass body.
Leave the jumper wire
between terminals 5 and 6
in place
L,N-230V~/50Hz
6.) Connection diagram EHR2KR(S)
3 4
Pump
65
L,N-230V~/50Hz
3 4
Pump
65
L,N-230V~/50Hz
3 4
Pump
65
1
3
Timer
Laing RTU
Jumper for automatic
pump shut-off
Jumper for automatic
pump shut-off
Jumper for automatic
pump shut-off
Rroom-thermostat
Laing RTS
6
L1 L2
L1 L2
L1 L2
Page view 5
1 2 3 4 5 6 7 8 9 10 11 12

Comments to this Manuals

No comments