Xylem 19 001 351R2 PACE Integrated Pump Controller Human User Manual

Browse online or download User Manual for Pumps Xylem 19 001 351R2 PACE Integrated Pump Controller Human. Xylem 19 001 351R2 PACE Integrated Pump Controller Human Machine Interface (HMI) for the Silent Storm VFD Pumping System – User Guide User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
PACE
TM
Integrated Pump Controller
Human Machine Interface (HMI)
for the Silent Storm VFD Pumping System
INSTRUCTION MANUAL
19-001-351R2
USER GUIDE
INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER’S USE.
Page view 0
1 2 ... 28

Summary of Contents

Page 1 - Integrated Pump Controller

PACETM Integrated Pump ControllerHuman Machine Interface (HMI) for the Silent Storm VFD Pumping SystemINSTRUCTION MANUAL19-001-351R2 USER GUIDEINSTALL

Page 2 - Acknowledgements

10 Figure 9: Flow Totals, Daily Flows Figure 10: Flow Totals, Weekly Flows Figure 11: Flow Totals Monthly Flows Figure 12: Flow Totals, Yearly

Page 3 - TABLE OF CONTENTS

11 Figure 14: Individual Pump Stats AUXILIARY EQUIPMENT STATUS Tap [Aux. Equipment Status] from the Operation menu. By tapping [Previous] or [Next],

Page 4 - TABLE OF FIGURES

12 Lake Level/Transfer/Timed Pump Monitoring Screen: Figure 17: Lake Level Controls Monitoring Screen This screen allows you to see the status of th

Page 5 - WARRANTY INFORMATION

13 NOTE: Be sure to scroll to the bottom of the alarm events list before using [Ack All] to ensure that all alarms have been viewed. Alarm notificati

Page 6 - HMI Overview

14 Figure 24: KWH Records, Daily Usage Figure 25: KWH Records, Weekly Usage Figure 26: KWH Records, Monthly Usage Figure 27: KWH Records, Year

Page 7 - Basic Screen Layout

15 Figure 29: Setup Menu, Supervisor USER SETUP Tap [User Setup] from the setup menu. This menu allows a supervisor to set the date/time, language,

Page 8 - Operation Menu

16 Figure 32: Individual Lockout Setup Figure 33: Parameter Tab in Lockout Setup The screen shown in Figure 32 sets up a lockout for Friday beginn

Page 9

17 AUXILIARY SETUP Tap [Auxiliary Setup] from the Setup menu. Some These screens allow you to setup and configure any auxiliary equipment. Check an

Page 10

18 pump will be allowed to run during the “enabled” period when the level in the controlled lake calls for the pump to run. If no level control is al

Page 11

19 Figure 39: Lake Level Controls Setup Timed Pump Setup (Non-Integrated only) This screen allows you to enable the timed pump setup. If the ‘Feedba

Page 12

2 Acknowledgements All materials ©2013 by Flowtronex, A Xylem company. Flowtronex® is a registered trademark of Flowtronex a Xylem Company. All right

Page 13

20 Figure 43: VFD Bypass Alternate SP Tap [Alternate SP] from the Options Setup Menu. Enter and store different alternate setpoints in the pop up sc

Page 14 - Setup Menu

21 Figure 47: Database Settings After enabling the database connection, the HMI must be restarted with the Gateway software running on the host irri

Page 15 - CAUTION:

22 Figure 48: Email Settings Occaisionally, the settings changes here may require restarting the HMI. Try this if you experience problems getting t

Page 16

23 Figure 49: Web Reports Menu Trend View Select [Trend View] from the Web Reports Menu. There are four key parts to the trends screen. Mean Valu

Page 17

24 Figure 51: Alarms & Events All reports can be printed using [Print], after a printer has been set up by clicking on [Print Setup]. Historical

Page 18

Appendix A–Glossary of Terms The terms used in this manual are defined in the Glossary of Terms. In addition, other industry specific or product-speci

Page 19

26 Filter A device used downstream of the pumps to clean the water being pumped into the irrigation. These devices are typically self-cleaning, but r

Page 20

27 Phase monitor A device that analyzes incoming voltage and determines whether all voltage parameters are acceptable and the phase sequence is corre

Page 21

Xylem Inc. 10661 Newkirk StreetDallas, TX 75220Phone: [email protected] is a trademark of Xylem Inc. or o

Page 22 - Web Reports

3 TABLE OF CONTENTSACKNOWLEDGEMENTS ... 2 ACKNOWLEDGEMENTS ... 2 INTRODUC

Page 23

4 TABLE OF FIGURESFigure 1: Basic Operation 7 Figure 2: Enhanced Key Pad 7 Figure 3: Basic Screen Layout 8 Figure 4: Log in Screen 8 Figure 5: Op

Page 24

5 WARRANTY INFORMATIONCompany warrants title to the product(s) and, except as noted below with respect to items not of Company’s Manufacturer, also w

Page 25 - Appendix A–Glossary of Terms

6 Introduction This manual is written for end users and is an introduction to the Xylem-Flowtronex® PACETM HMI (Human Machine Interface). The HMI is

Page 26

7 Figure 1: Basic Operation TYPICAL PUMPING OPERATION Several common control variables including flow, pressure, and level are used for operating an

Page 27

8 navigate to other key areas of the application. The content of the navigation bar changes depending on what type of user is logged in. 2. The Heade

Page 28 - Xylem Inc

9 Figure 5: Operation Menu SYSTEM VIEW & TRENDS Tap [System View] from the Operation menu. System View accesses color-coded operational trends o